PAGE 14 of 60 VX2200 TECHNICAL MANUAL VER1.4
FUNCTIONAL DOOR PANELS
Functional units are available in the 4000 Series, 800 Series and vandal resistant series. They allow panels
with individual call buttons to be connected to the VX2200 “2 wire” BUS. They incorporate the functional
interface connections with the speaker unit and are available with 0, 1& 2 button versions (4000 Series can
also have 1D, & 2D buttons).
These device allow the connection of up to 64 functional push buttons using standard extension module
panels from the 800 and 4000 series range (Vandal resistant panels call also have up to 64 push buttons). If
a number of push buttons greater than 64 is required, more VX2203M modules can be used to have up to
180 buttons and up to 255 with the low cost intercom Art.3161.
Operation
Once the unit has been programmed and connected correctly, it will generate on each pressing of a push
button, a code corresponding to the PHONE ID (address programmed on the 8 way dip-switch inside each
telephone) of the telephone being called.
To call a user:
press the relevant button: 5 quick beeps will indicate if the system is busy, otherwise the call will be signalled
by a slow intermittent acoustic signal until the call is answered, the conversation time expires (programmable
time) or the call is interrupted by pressing a push button for a minimum of 2 seconds. A short intermittent
acoustic signal indicates that the door is open. If a wrong push button is pressed or if there is no answer, a
new call will erase the previous one.
Programming
The programming is carried out exclusively through the configuration of the 2 jumpers the 8 way Dip-switch
on the back side of the unit. Depending on the 2 jumper settings, the 8 way Dipswitches have a different
function.
WITH THE TWO JUMPERS IN THE LEFT POSITION (TO WORK WITH 900 & 3000 SERIES EXCEPT
INTERCOM 3161 & 3162), THE 8 WAY DIP-SW ENABLES THE FOLLOWING:
- Program the unit as a Master or a Slave (switch 1);
- Program the 64 push buttons group (switches 2 & 3);
- Program the conversation time (switch 4);
- Program the door opening time (switch 5);
- Program the device number (switches 6,7,8);
CONFIGURATION ON THE UNIT AS A MASTER OR SLAVE
Switch Nr.1 Setting Up
OFF = Slave
ON = Master (default)
PROGRAMMING THE 64 PUSH BUTTON GROUP
Switch Nr.2 Nr.3 Settings
OFF OFF from buttons 1 to 64
ON OFF from buttons 65 to 128
OFF ON from buttons 129 to 180
ON ON from buttons 1 to 64 with 900 series devices
Switches 2 & 3 define the range of Phone IDs generated by the unit when the call buttons are pressed. For
example with dip-switch 2 and 3 both OFF, the push button connected between the VX2203 terminals “1
and “a” generates the ID PHONE 1 while the same push button, with dip-switch 2 ON and dip-switch 3
OFF, will generate the PHONE ID 65. The fourth range of push button groups can be used with the 900
series intercoms and video intercoms.
PROGRAMMING THE CONVERSATION TIME
Switch Nr.4 Setting Up
OFF = 1 min
ON = 2 min
PROGRAMMING THE DOOR OPEN TIME
Switch Nr.5 Setting Up
OFF = 2 seconds
ON = 6 seconds
PROGRAMMING THE DEVICE NUMBER
Switch Nr.6 Nr.7 Nr.8 Setting Up
OFF OFF OFF = 1
ON OFF OFF = 2
OFF ON OFF = 3
ON ON OFF = 4
OFF OFF ON = 5
ON OFF ON = 6
OFF ON ON = 7
ON ON ON = 8