PAGE 41 of 60 VX2200 TECHNICAL MANUAL VER1.4
Connections
Terminal Signal Description
1 +20V
Video power supply input 17-20Vdc
2 +20V
Video power supply input 17-20Vdc
3 GND
Video power ground connection
4 GND
Video power ground connection
5 V2/V
Balanced video V2 input or coax centre core (Set by 4 way dip-switches)
6 V1
Balanced video V1 input
7 L
Data/speech bus input
8 GND
Bus ground
9 LB
Local door bell input (Switched to ground to trigger)
10 AL
Alarm button input (Switch to ground to trigger)
11 GND
Ground
12 S1
S1 push button (Shorts to Ground when pressed)
13 S2
S2 push button (Shorts to Ground when pressed)
14
zz
zz push button (Latching toggle action)
15 +VD
+12Vdc output to power video distribution unit (Art. 894)
16 GND
Ground
17 12VO
Regulated 12Vdc output
18 12VI
+12Vdc power supply input
19 LD
Auxiliary LED +12V input
20 GND
Ground
5478 PROGRAMMING
Setup is carried out using the push buttons on the front of the unit and the dip-switches located on the rear of
the unit. An eight way dip-switch bank is used to set the address of the apartment as shown in the
decimal/binary conversion chart in this manual. Additionally there is a 4 bank dip switch which is used to
select the video type (either coaxial or balanced video twisted pair).
4 WAY DIPSWITCH
1 2 3 4 Video Mode
ON ON OFF ON Coaxial video (V2 = V)
ON ON ON OFF Balance video
Switches 1 and 2 adjust the video signal impedance. When using more than one videomonitor (in parallel
without a video splitter) put both switches in the OFF position on all but the last videomonitor (end of line).
Additional programming options include:-
Number of rings (Factory default = 6 rings)
Press and hold (for approx 10 seconds) the “
” button until the LED next to the button illuminates
and the unit emits a beep.
Press again the “
” button as many times as the number of rings needed (i.e. 6 times = 6 rings,
maximum 9 times).
Once the value of rings has been reached, wait 5 seconds for a beep and the LED turning OFF.
The new value is stored.
Vista de página 40