PAGE 27 of 60 VX2200 TECHNICAL MANUAL VER1.4
the concierge will return to stand-by mode.
Operation notes
a. To use the letters from “E” to “H” press twice the relevant button: “A” becomes “E”, “B” becomes “F”, “C”
becomes “G” and “D” becomes “H”;
Opening the speech from the concierge to a door station without being called first
With the concierge in DAY or NIGHT mode, pick up the handset, select a number from 1 – 9 (For doors
addressed from 1 – 9) and then press the “n” button. The display will show ‘SPEAK’ once the speech path
has been established.
Opening a door from the concierge without being called first
With the concierge in DAY or NIGHT mode, pick up the handset, select a number from 1 – 9 (For doors
addressed from 1 – 9) and then press the “
” button. The display will show ‘DOOR OPEN’.
Programming via the concierge keypad and display
The “VX2210 PROGRAMMING” flow chart shows how to proceed with the programming of the unit.
During the data input, the “*” button confirms the programmed data while if an error occurs, the “#” button will
delete the programmed data
1. Remove the supply from the concierge (disconnect the Concierge cable from the wall connection or
power down the whole system);
2. Press “*” button and reconnect the supply to the unit (connect the Concierge cable or power up the
whole system), then release the button;
3. The display will show “MEM LOCATION:”, enter on the keypad the number (from 1 to 254) of the
memory location to store/modify and confirm by pressing “*” button. Pressing the “*” button twice at this
step without inserting any data, causes the exit from programming mode and the concierge is switched
back to “night” mode.
4. The display will show “FLAT:”, enter the flat code on the keypad (an alphanumeric string of 6 char max)
or leave unchanged (if one is present) and then confirm with “*” button;
The display will show “ID PHONE:”, type the phone ID (already programmed by means of the Dip-switch
inside the VX2200 telephones, it is a number from 1 to 180) or leave unchanged then press “*” button.
Programming via the concierge RS232 connection
The RS232 connection can be found on the top edge of the concierge (Jack socket). Connect the lead
supplied with the programming software kit between the jack socket and the serial port of the PC. The
concierge must be switched into OFF mode when programming. To do this, press the “n” button on the
concierge telephone repeatedly until the display shows ‘OFF’. To program via the PC follow the instructions
supplied with the PC software (Note. Follow the same procedure to program the Concierge as would be
used to program a digital door panel).
In addition to the programming carried out through the keypad, the concierge has an internal 4 way dip-
switch that adjusts the following settings:
Switch Status Operation
OFF
1
ON Divert a call to the addressed 180 after 20secs without an answer.
OFF
2
ON Enable parallel connection of 2 concierges. This switch must be set “ON” for Both concierges.
OFF
3
ON Enable the use of Art.2204 isolation PCB’s.
OFF
4
ON
Disable alarm reception. Alarms can instead be processed by one or more Art.512DR if installed
in the system and addressed as 255.
Two adjustment POT’s are also located within the concierge. The one to the right of the PCB adjusts the speech balance
towards the apartments and the one to the left adjusts the speech balance towards the doors.
Programming Notes
a. The programming (combining the phone ID address and the apartment number) must be the same as “2202” door units or must
correspond to the call button on the unit “2203” in order to have the correct flat number on the concierge display.
b. During the programming, the system is off line and no calls will go through;
c. The insertion of incorrect values is indicated by error messages. The unit will wait for a correct input before moving on.
Technical specifications
Memory capacity : 254 memory locations
Working voltage : 13 Vdc +/- 10%
Max. absorption : about 350 mA
Working temperature : -10 +50 C°